Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

My ideas: Drainage and Utilities

Showing 114

Open API to programmatically create Feature Definitions and Feature Symbologies.

It would be extremely helpful, if we were able to programmatically create Feature Definitions and Feature Symbologies so that automation of the creation of new 'Custom Drainage Features' every time a drainage structure had a different bottom box (...
over 1 year ago in All Other / Drainage and Utilities / OpenRoads Designer / OpenSite Designer 3 Future consideration

Ability to Place a Conduit/Pipe "Without" a Node

Many times, we have conduits/pipes that simply daylight a surface and drain on to the ground or into a pond. Please add the ability to place conduit/pipes "Without" the need of a Node. I understand that we can create a sort of null point/node that...
about 2 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Drainage Profile Change Property (Color/linestyle)

Currently, Profiles are drawn according to the feat definition/element templates of a node and/or conduits. There are times we need to differentiate the difference between an existing network vs proposed. eg. all proposed are required to be solid ...
4 months ago in Drainage and Utilities 1 Future consideration

ORD Drainage - new properties for gutter spread/depth at edge of grate (not center)

Ohio DOT likes to see the spread and depth at the edge of the grate. Currently the software reports on the spread and depth at the start and end of the gutter. Would like additional properties to also report the spread and depth at the edge of the...
10 months ago in Drainage and Utilities 0 Needs review

Parametric capability for the placement of Node and Conduit feature definitions

This would dramatically reduce the requirement for a vast number of library cells and feature definitions to be created
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Allow the road slope to exceed the gutter cross slope

My state agency commonly uses gutters with a 4% cross slope. The maximum superelevation rate is 7%. The gutter slope stays at 4% in this situation. Spread does not compute in this scenario because "A depressed gutter must have a Gutter Cross Slope...
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add support for slope manipulator in profile when the "Use Construction Length and Slop" Preference = True

when the "Use Construction Length and Slope" Preference = True", in the profile view the slopes can not be edited. c If the "Use Construction Length and Slope" Preference is set to False, We can edit the slope value directly in the profile. Please...
4 months ago in Drainage and Utilities 0 Needs review

ORD Drainage/Utilities - Make Item Types Attached through Feature Definitions visible outside ORD

Based on service now case CS0300323, item types attached to drainage/utility nodes through feature definitions are not visible in MicroStation or i.dgns. However, if the item types are attached manually to nodes they are visible outside the civil ...
22 days ago in Drainage and Utilities / Workspace 0 Future consideration

ORD SUDA - drainage profile view

Currently when profiling a Utility (nodes and conduits), the lines on the nodes and conduits are "closed". Old Inroads Storm/Sanitary had open connections. Agency we submit the plans want us to show that connection as open. Only option at the mome...
6 months ago in Drainage and Utilities 3 Future consideration

DU tool to update node name by feature definition

The name of the nodes are defined at placement by the selected Feature Definition. It's common for it to be changed during the design process. For these cases, all altered nodes must be manually renamed. This usually is done through selection or u...