Add shear stress calculation (based on HEC-15) to conduit data.

Conduit data has flow data but not shear force data which would help design the channel lining needed to protect from ditch/channel erosion. https://www.fhwa.dot.gov/engineering/hydraulics/pubs/05114/05114.pdf

Openroads Drainage - HGL versus Headwater Analysis for Headwalls Inletting into a Storm Sewer System

Many times, a stream needs to be drained into a storm sewer system via a headwall. When this occurs, two analysis should be considered: The headwater at the headwall (the mechanics of the water getting into the pipe at the headwall). Generally KYT...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

ORD Drainage - Show actual Tc versus Tc Minimum

Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

SUDA - Spread Slope

Make it easier to manage longitudinal spread slope. It's nice to input the slope in the properties per node, but consider making it integrated to the gutters used during bypass flow drawing of gutters.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Make Grips Visible and Useable on 4k displays

When using Grips for Structures and Pipes - the grip blends too much into the background color, and on a 4K screen is TINY. The pipe grip is annoying to select (it only appears when I select the centerline of the pipe) but when adjusting or swapin...
11 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 1 Future consideration

Ablity to connect two nodes directly by flange

For the water supply project, in a situation where we have cast iron elements connected to the flange such as gate valves, hydrants, elbows, venturiers and plastic line pipes. There is no way to connect the two nodes directly through the flange. a...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add report for information about pipe bends

Kindly add a non-graphical way of identifying whether a pipe contains bends or not and information about the coordinates. The report is required to produce pipe setting out schedules and share the coordinates with the contractor. It would be...
11 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add Offset Format options to the Baseline Offset Text Favorite

Add the Offset Format options that are available for the Point Offset text favorite (Positive Prefix, Negative Prefix, Positive Suffix, Negative Suffix, and Show Sign) to the Drainage Baseline Offset text favorite.

Utility Enhancements

Add the conduit table options similar to drainage for managing conduit sizes, materials, etc... Right now you have to input a conduit table for each utility type and can't import a table from utility to utility. Just need one set of tables to mana...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / Workspace 0 Future consideration

Add the ability to place banks of conduits.

Electrical and Communications conduits are usually placed in banks of multiple conduits of say 12 conduits which may be of different sizes.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration