Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 118

Oklahoma Time of Concentration Formula

Currently ORD does not have an option to calculate Time of Concentration for the channel flow that the state of Oklahoma uses. This eliminates the option to use the programmed Tc calculator for channel flow. I need an option to put in my own formu...

DU Analytic Symbology Improvement

When i call a Feature Definition in a text favorite or in my element symbology (Analytic Symbology), it allways comes with it's path. It's usually a long path and it just mess my view display with too much info. The ability to just show the name w...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 2 Planned

Calculation column in drainage and utilities flex table.

A formula could be made using existing columns to calculate a value that is atypical or not an option otherwise. I need a pipe full flow velocity check for a design. I can use excel to calculate using full flow capacity and full flow area but if t...
about 2 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Already exists

ORD Drainage - Make item Type Properties available in flex tables.

when adding columns to flex tables we need the ability to add item type properties to the flex tables. similar to how we can create UDX properties and show them on flex tables.
11 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Create a rule to set drainage node to (active terrain) when setting elevation reference

Presently when setting reference elevation for the node it lets you set it to the active terrain but does not rule it to the (active terrain). If this were done the inlet tops would automatically adjust as the design terrain changes.
about 2 years ago in Drainage and Utilities 1 Already exists

DU: add drop calculation to node invert depending on lowest conduit wall thickness

Some times, most common with concrete conduits, the node invert needs to have a drop in reference to the lowest pipe to acomodate its wall. This would later be filled to match.For construction and BIM purpose, this difference is important. Special...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 3 Already exists

DU conduits external wall controled by Feature Symbology

We have the option to define a template to pipes external walls, but only through the feature definition. For all other elements of the pipe, OR allows for feature symbology. From my experience, symbologys work better and are more constant.
3 months ago in Drainage and Utilities 2 Needs review

Add ability to set default Engineering Libraries for all users

As it stands, I can make a new Engineering Library on a network drive to share with other users, but if I wanted to make that library the "default", I can't without having to make the change for each individual user.
3 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Separate 3D line and 3D object for pipes to different levels.

In Drainage & Utilities, the 3D line and the 3D object for a pipes(conduit/link) is placed on same level. It would be great to have them on different levels - also because it can be a demand from from clients in Denmark, that the line is place...
7 months ago in Drainage and Utilities 1 Needs review

Allow Design Scenarios to change proposed conduit properties and class based on depth of conduit.

The class of a pipe is primarily selected by the depth of cover over a pipe. Sometimes vehicle loads or construction loads have an influence on the class selection
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration