Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 114

External model checking process - by possibly running a report to identify where 3d conduit string lines have been placed - i.e soffit, centre, invert, crown or base, this will ensure all output data of conduits are consistent for construction.

This is useful to enable a) - checks to be carried out, b) - to identify possible conduits that require amending - to align with all others. This will enable consistent and accurate output data to be produced, that can be used to construct from.
9 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Display and Annotate Tap Nodes in Profile Drawing

The feature name (e.g. a number) of the tap node can be labeled in the plan.The tap is visible in the "Engineering Profile".It would be helpful if this could also be displayed and labeled in the profile view/drawing. How it should work: Tap Node i...
about 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

limit the number of Rows in the Elevation-Area Table.

I get close to 40-50 rows of data when I assign a "pond" to a terrian. I only need data every 0.1ft but it is providing much more.
about 1 year ago in Drainage and Utilities 0 Future consideration

Allow Conduits from different "families" to connect to the same node.

Add support for nodes that accept multiple types of conduit families.
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Ditches be channel features

It would be wonderful if ditches were channel features so that they could be treated as surface features like gutters are to get head on inlet.

Custom Grate Spacing and Sizes

It would be amazing if we could utilize our own grate spacing for calculating the head on inlets. KYTC has several grates that don't quite match with what is in the delivered system, and this may affect the depth of the head on the inlet.

Element Templates Point to Multiple Cells

At KYTC we like to show the vaults of drainage structures, in order to do that S&S drew them for us. ORD does that in 3D, however, we turn the 3D off when producing plans. It would help in the case that we could point to two cells (one that ma...

Profile Annotation Groups

A lot of our project show multiple profiles in one profile view (EG, Proposed PGL, RT Gutter, LT Gutter, etc.). In MicroStation we set up a specific .ddb file that would plot the text labels in the desired location. We haven’t been successful in c...

DU RIM Elevation calculated from Ground Elevation offset

The RIM Elevation is a stagnant number once you enter an elevation it does not update in relation to any surface changes. RIM Elevation would be better suited for use if it can be defined with an offset. Another field would be needed: RIM Depressi...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 0 Future consideration

Simplfy the Interface - How many "sizes" can there be?

Object Properties - Feature Definition of a pipe is top level, its description is a pick list of diameters (TxDOT), but Utilities Properties has three different locations. This complexity is unnecessary.