Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Applications

Showing 1263 of 1410

Single Offset Partial/Entire Element creates complex elements with the ability to add/remove tapers

One of the factors prohibiting the use of civil geometry in plan production is that it can often feel cumbersome to implement design changes without 'breaking' your previous work. Let's say you have an intersection designed using civil geometry, a...
10 months ago in Geometry / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Enhancement in Approach Slab and Deck

Approach Slab - When placed, we cannot switch the template - Approach Slab reference line text annotation scale and font are different to bridge support line, it doesn't follow the model annotation scale - Option to derive the length of the slab, ...
7 months ago in OpenBridge Modeler 0 Future consideration

Flow Arrow from High to Low Point for any Civil/Linear Geometry

In placing drainage node to the carriageway or kerb/curb lines in 2D plan, it is useful to show the flow arrow from high point to low point for the drainage engineer. Currently, the flow arrow is only available in "Terrain", but not civil geometry...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Already exists

Printing multiple signs to a single pdf.

With the ability to open multiple signs at once, it would be nice to be able to print all of the open signs to a single pdf. It would also be nice to have a print shortcut on the standard toolbar at the top of the ribbon instead of having to click...
over 1 year ago in OpenRoads SignCAD 0 Future consideration

Point Control lock to to start and lock to end option should honor the corridor start and end limits

Actually , the lock to start and lock to end stations are defined by the start and end of alignment or feature the corridor it is based on. This makes the point control handles (in the 2d view) to be outside the corridor limits when the corridor i...
almost 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Incorrect arc radius for turnout outer curve switch.

For turnout annotation, we need to add turnout with LLS Extension from the library. I know that it is possible to add LLS radius value for a defined curved turnout in the library, but for a complex project where there are a lot of curved turnouts ...
3 months ago in OpenRail Designer / Turnouts/Crossings 0

No subtraction of sleepers from ballast in corridor report

Corridor report does not subtract the volume of sleepers we added to the model from the ballast. I propose to add in the next version of ORD the possibility to subtract in the ballast the added sleepers.
3 months ago in OpenRail Designer / Reports 0 Future consideration

No possibility to set the lower limit height of the profile

When creating profiles using ,,Named Boundary”, I cannot set the lower height limit of the profile. I propose to add in the next part of ORD setting the lower height limit if we want to make one drawing sheet from profile. This would help with the...
3 months ago in Drawing Production / OpenRail Designer 1 Already exists

Frame action or double curvature to be considered when superstructure is integral with substructure

When a superstructure is integral to substructure for Leap Concrete, both girders in the superstructure module and columns in the substructure module analysis/ design should incorporate frame action for any design load cases such as breaking force...
3 months ago in OpenBridge Designer 0 Future consideration

Cross section view should show Point name of a template drop

when using the point control function. It is expected to see the names of points of a template drop in the cross section view. This would be utilized when using the point control function.
almost 2 years ago in Drawing Production / OpenRail Designer / OpenRoads Designer / OpenSite Designer 4 Already exists