Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 23

Ability to Place a Conduit/Pipe "Without" a Node

Many times, we have conduits/pipes that simply daylight a surface and drain on to the ground or into a pond. Please add the ability to place conduit/pipes "Without" the need of a Node. I understand that we can create a sort of null point/node that...

Add support for slope manipulator in profile when the "Use Construction Length and Slop" Preference = True

when the "Use Construction Length and Slope" Preference = True", in the profile view the slopes can not be edited. c If the "Use Construction Length and Slope" Preference is set to False, We can edit the slope value directly in the profile. Please...
3 months ago in Drainage and Utilities 0 Needs review

ORD Drainage - new properties for gutter spread/depth at edge of grate (not center)

Ohio DOT likes to see the spread and depth at the edge of the grate. Currently the software reports on the spread and depth at the start and end of the gutter. Would like additional properties to also report the spread and depth at the edge of the...
8 months ago in Drainage and Utilities 0 Needs review

DU conduits external wall controled by Feature Symbology

We have the option to define a template to pipes external walls, but only through the feature definition. For all other elements of the pipe, OR allows for feature symbology. From my experience, symbologys work better and are more constant.
about 1 month ago in Drainage and Utilities 2 Needs review

Separate 3D line and 3D object for pipes to different levels.

In Drainage & Utilities, the 3D line and the 3D object for a pipes(conduit/link) is placed on same level. It would be great to have them on different levels - also because it can be a demand from from clients in Denmark, that the line is place...
5 months ago in Drainage and Utilities 1 Needs review

Enable hydraulic analysis for referenced files

For large projects, we need the ability to have multiple engineers working on the hydraulic model. We can achieve this by splitting the pipe network into multiple files and creating catchments in separate files. Doing so causes us to lose the abil...

DU: Only modelling workflow

When starting a DU, OpenRoads creates a whole DU project inside the file and brings a lot of hidroly/hidraulic properties with it. That's fine if the goal is to run an analysis. But what if I just want to model a whole network and never run it? Di...

Automate the assignment of a node's sump offset based on largest connecting pipe's wall thickness

We are looking for a workflow where the Sump depth value can be set to the thickness of the "largest pipe" connected to a node. When the user places a node, if there is an option to set the sump depth to the thickness of the pipe, then it would au...

Automatically adjust structure Hight to include pipe thickness

it would be more accurate to calculate the structure Height if when a pipe is connected to a structure that the bottom base slab was adjusted to be below the wall of the pipe. this would also make the 3D model look better.

SUDA - Spread Slope

Make it easier to manage longitudinal spread slope. It's nice to input the slope in the properties per node, but consider making it integrated to the gutters used during bypass flow drawing of gutters.
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review