Currently ORD does not have an option to calculate Time of Concentration for the channel flow that the state of Oklahoma uses. This eliminates the option to use the programmed Tc calculator for channel flow. I need an option to put in my own formu...
When i call a Feature Definition in a text favorite or in my element symbology (Analytic Symbology), it allways comes with it's path. It's usually a long path and it just mess my view display with too much info. The ability to just show the name w...
ORD Drainage - Make item Type Properties available in flex tables.
when adding columns to flex tables we need the ability to add item type properties to the flex tables. similar to how we can create UDX properties and show them on flex tables.
Create a rule to set drainage node to (active terrain) when setting elevation reference
Presently when setting reference elevation for the node it lets you set it to the active terrain but does not rule it to the (active terrain). If this were done the inlet tops would automatically adjust as the design terrain changes.
DU: add drop calculation to node invert depending on lowest conduit wall thickness
Some times, most common with concrete conduits, the node invert needs to have a drop in reference to the lowest pipe to acomodate its wall. This would later be filled to match.For construction and BIM purpose, this difference is important. Special...
Calculation column in drainage and utilities flex table.
A formula could be made using existing columns to calculate a value that is atypical or not an option otherwise. I need a pipe full flow velocity check for a design. I can use excel to calculate using full flow capacity and full flow area but if t...
DU conduits external wall controled by Feature Symbology
We have the option to define a template to pipes external walls, but only through the feature definition. For all other elements of the pipe, OR allows for feature symbology. From my experience, symbologys work better and are more constant.
Separate 3D line and 3D object for pipes to different levels.
In Drainage & Utilities, the 3D line and the 3D object for a pipes(conduit/link) is placed on same level. It would be great to have them on different levels - also because it can be a demand from from clients in Denmark, that the line is place...
Add ability to set default Engineering Libraries for all users
As it stands, I can make a new Engineering Library on a network drive to share with other users, but if I wanted to make that library the "default", I can't without having to make the change for each individual user.
Allow Design Scenarios to change proposed conduit properties and class based on depth of conduit.
The class of a pipe is primarily selected by the depth of cover over a pipe. Sometimes vehicle loads or construction loads have an influence on the class selection