Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 99 of 1164

Simplfy the Interface - How many "sizes" can there be?

Object Properties - Feature Definition of a pipe is top level, its description is a pick list of diameters (TxDOT), but Utilities Properties has three different locations. This complexity is unnecessary.

Auto Create Event Points at Drainage Nodes

CTDOT would like the ability to create event points from Drainage Nodes. Many of our projects have a lot structures and manually adding event Points at each crossing is tedious. Projecting drainage on XSCs still does not work like we need it to, s...
5 months ago in Drainage and Utilities / Geometry / OpenRail Designer / OpenSite Designer 1 Planned

Add profile annotation location option for annotating conduit description only once

If a conduit is perfectly straight, then it is easy to put the description once in the middle, but if the conduit has any bends then each segment gets annotated. Adding an option for annotation frequency with location controls would fix this.
over 1 year ago in Annotation / Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Ablity to connect two nodes directly by flange

For the water supply project, in a situation where we have cast iron elements connected to the flange such as gate valves, hydrants, elbows, venturiers and plastic line pipes. There is no way to connect the two nodes directly through the flange. a...
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Make Grips Visible and Useable on 4k displays

When using Grips for Structures and Pipes - the grip blends too much into the background color, and on a 4K screen is TINY. The pipe grip is annoying to select (it only appears when I select the centerline of the pipe) but when adjusting or swapin...
3 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 1 Future consideration

Gutter spread - flip side

Why do gutters not have a "side" as spread when drawn appear in the right side.

If no Design Lenghts in Catalog - Ignore or Set Design Inlet Openings to false

I do not see a place to force in a Inlet Catalog to set "Design Inlet Opening" to false, so I would like the software to assume False if lenghts are NOT in the catalog.

Add report for information about pipe bends

Kindly add a non-graphical way of identifying whether a pipe contains bends or not and information about the coordinates. The report is required to produce pipe setting out schedules and share the coordinates with the contractor. It would be...
3 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add reflect option for DU cells.

Implement a way to minimize the number of cells by allowing reflecting and mirroring of nodes during placement and manipulation.
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

ORD Drainage - Show actual Tc versus Tc Minimum

Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
10 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration