Re-word the Upgrade dialog to include that the file will also be 'aligned' to the product.

There are several ways a file can be opened though local access, networking, and ProjectWise. There is very minimal documentation available to explain to users the difference between Upgrading and Aligning a file. Not to mention how, when, and why...

Reattach Corridor on linear templates

Reattach corridor was recently disabled for linear templates and the only way to edit such corridor is to create new one from the scratch.
10 months ago in Modeling / OpenRail Designer / OpenRoads Designer 0 Future consideration

Retain or be able to re-associate references when "One DGN Per Sheet" used to facilitate ProjectWise Integration

Many companies/DOT's use ProjectWise Explorer Client which will apply attributes such as sheet number and total sheets to sheet models via tags. The only way to apply this on multiple sheets is to use the "One DGN Per Sheet" option. If a reference...

Request for Additional Pavement Striping Options in ConceptStation

This is a request for more pavement striping options to be available for placement in ConceptStation. For example, yield line under Linear Marking tool.
9 months ago in OpenRoads ConceptStation 0 Future consideration

Calculation of track length

A function that calculates the length of the tracks with turnouts withdrawn would be very helpful to calculate the amount of rails. The lengths of rails between turnout points 1 - 2 and 1-3 should be automatically redrawn from the lengths and repo...
4 months ago in Analytics / OpenRail Designer 0 Future consideration

Bring back the “NE=” key-in command.

U.S. surveyors traditionally work in Northing & Easting, in that order. When working with Microstation V8i, AND with Inroads loaded, the user could perform precision drafting by using the “NE= “ key-in to enter the exact northing/easting coord...
almost 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 4 Future consideration

Add an option to include "Profile" when offsetting Geometry

There should be an option to include the Profile when offsetting geometry if desired. Currently we need to offset the geometry and then copy the profile. It would be much more intuitive if there was an option to just include the profile when initi...
over 1 year ago in Geometry / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Name Changing Per Drainage Structure

When naming nodes, we usually associate that node name with the conduit, drainage area, and gutter name. But, if we have to update the node name (ex: 0401 to 0405), then we have to change all the other names manually. User is looking for possibili...
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 3 Future consideration

Turnout Creation Wizard

Developing turnouts in the new software can be quite cumbersome. If there was a wizard that allowed users to input known common pieces of geometry in a more descriptive and graphical fashion, it would help significantly. When geometry elements are...
over 2 years ago in Geometry / OpenRail Designer 3 Future consideration

Bridge drainage system

OpenBridge does not seem to have a dedicated functionality for drainage system. I have seen solution in OpenBuildings, it looks quite decent. Just to clarify, when I refer to a drainage system, I mean elements like drip pipes, scuppers, vertical p...