Applications

Showing 1226

LFD Load Rating in LEAP Steel

NYSDOT requires that all plan sets include an LFD Load Rating. Until this ability is added to LEAP Steel, we cannot adopt OpenBridge fully and must continue doing our steel design in different software.
about 1 year ago in OpenBridge Designer 2 Future consideration

Make Grips Visible and Useable on 4k displays

When using Grips for Structures and Pipes - the grip blends too much into the background color, and on a 4K screen is TINY. The pipe grip is annoying to select (it only appears when I select the centerline of the pipe) but when adjusting or swapin...
9 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 1 Future consideration

Checkbox to turn on-/off alignments

It would be useful to be able to turn on-/off single alignments. Perhaps with a checkbox in the "OpenRail Model" section in the explorer, just like the ones in the "Feature definition" section in OpenRail Standards. This could probably be handy wi...
about 1 year ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 0 Future consideration

Text Favorite cross section slope - hide trailing zeros

We are able to format most text favorites to hide trailing zeros. However, we are not able to hide trailing zeros for text favorites for Cross Section Annotations > Segments > Slope. We can define the precision, but there is no option to hid...
about 1 year ago in Drawing Production / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Update turnout library for concept station

Clearly, concept station has a lot of potential as a conceptualization tool. However, just as any other tool at its birth, has issues that needs to be adressed. I noticed that the turnout library for swedish turnouts is outdated: it does not have ...
9 months ago in OpenRail ConceptStation 0 Needs review

Separate geometric ratios summary from stress ratio summary

OpenBridge LEAP Steel Summaries include geometric ratios (like 6.10.7.3-1) together with stress ratios. This is not helpful, as that ratios is not a real demand/capacity ratio, therefore when that geometric value of "performance ratio" is high, it...
3 months ago in OpenBridge Designer / Reports 0 Future consideration

Add a position tick mark to the Survey Decorators

Inroads allowed the user to toggle a tick mark, such as a plus symbol (+), to show the position of any survey point in the fieldbook. Very useful. ORD allows the toggling of many different attributes of a point by using Survey Decorators. Please a...
over 1 year ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 0 Future consideration

GEOPAK-like Drainage Tools

I would like to see tools added to ORD that would mimic the Drainage Tools found in GEOPAK. Specifically, I would like to be able to visualize Drainage Patterns. I envision this be something that could be added to a Terrain Feature Definition, sim...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / Terrain 2 Future consideration

Export Autodesk DWG

Please return the export to DWG/DWF functionality available in previous versions. Not every customer uses Microstation DGN files.
about 1 year ago in OpenRoads SignCAD 0 Will not implement

Trim with Connection Points/Regions on opposite sides of cell

I would like to have the ability to put connection regions and connection points on opposite ends of cells, specifically aprons. Currently, the apron won't trim with this setup.