Add option for suffix (pos and neg) to Slope Format

In format options for slope annotation we can define prefix for positive and negative values. please add the option to add a suffix. This would allow to annotate for example XS Slopes like so: <2.0% this way or 2.0%> the other way
over 1 year ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Set cant parameters before applying

Make the Cant tool more useful. Currently, we set the speed then apply cant and it spits out some random cant values, which are unrealistic. Then we can set the cant parameters and the software proves the values are unrealistic and we have to edit...
10 months ago in CANT / OpenRail Designer 1 Needs review

Plan annotation based on element length

A feature to define within the Annotation Group for plan alignment annotation and vary the text favourite used based on element length. For example, I would like to use a text favourite with transition geometry text on 1 line for elements greater ...
over 1 year ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Automatic/batch update of Profile 3D cut

This won't update immediatly when the 3D model is updated. This means that when going to plan production, all profiles needs to be refreshed.
about 2 years ago in Geometry / OpenRail Designer / OpenRoads Designer 3 Future consideration

Gutter spread - flip side

Why do gutters not have a "side" as spread when drawn appear in the right side.
10 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

If no Design Lenghts in Catalog - Ignore or Set Design Inlet Openings to false

I do not see a place to force in a Inlet Catalog to set "Design Inlet Opening" to false, so I would like the software to assume False if lenghts are NOT in the catalog.
10 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Needs review

Create a Reference Link to a Project Template LIbrary File

Users would like the ability to maintain a link to the project template library, so that each time they don't have to browse and locate the .itl file. Because users store the file at different locations in ProjectWise, maintaining a link from the ...
10 months ago in Modeling / OpenRoads Designer 9 Already exists

Regression/ best fit line added to Opensite Designer

Please add regression/ best fit line added to Opensite Designer and not jsut open roads designer
over 1 year ago in OpenSite Designer / Regression Analysis 0 Future consideration

Ability to turn off Mesh (components) in reference files

There should be a way to turn off Mesh (components) in reference files. Currently, if you untick the "Mesh" Feature Definition from ORD Standards in explorer, it only turns off Mesh Components within the active model. The Mesh components that use ...
over 1 year ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 2 Future consideration

Allow manual input of acre area when manually defining a catchments subareas

Currently when manually defining a catchments subareas we are only able to hard code in a percentage of the total drainage area instead of the acreage of that subarea (see attached file). This causes us to have to manually calculate the percentage...