Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 106 of 1282

Add support for slope manipulator in profile when the "Use Construction Length and Slop" Preference = True

when the "Use Construction Length and Slope" Preference = True", in the profile view the slopes can not be edited. c If the "Use Construction Length and Slope" Preference is set to False, We can edit the slope value directly in the profile. Please...
about 1 month ago in Drainage and Utilities 0 Needs review

Drainage Profile Change Property (Color/linestyle)

Currently, Profiles are drawn according to the feat definition/element templates of a node and/or conduits. There are times we need to differentiate the difference between an existing network vs proposed. eg. all proposed are required to be solid ...
about 1 month ago in Drainage and Utilities 1 Future consideration

Open API to programmatically create Feature Definitions and Feature Symbologies.

It would be extremely helpful, if we were able to programmatically create Feature Definitions and Feature Symbologies so that automation of the creation of new 'Custom Drainage Features' every time a drainage structure had a different bottom box (...
over 1 year ago in All Other / Drainage and Utilities / OpenRoads Designer / OpenSite Designer 3 Future consideration

ORD Drainage - new properties for gutter spread/depth at edge of grate (not center)

Ohio DOT likes to see the spread and depth at the edge of the grate. Currently the software reports on the spread and depth at the start and end of the gutter. Would like additional properties to also report the spread and depth at the edge of the...
7 months ago in Drainage and Utilities 0 Needs review

ORD SUDA - drainage profile view

Currently when profiling a Utility (nodes and conduits), the lines on the nodes and conduits are "closed". Old Inroads Storm/Sanitary had open connections. Agency we submit the plans want us to show that connection as open. Only option at the mome...
3 months ago in Drainage and Utilities 3 Future consideration

Allow the road slope to exceed the gutter cross slope

My state agency commonly uses gutters with a 4% cross slope. The maximum superelevation rate is 7%. The gutter slope stays at 4% in this situation. Spread does not compute in this scenario because "A depressed gutter must have a Gutter Cross Slope...
12 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Parametric capability for the placement of Node and Conduit feature definitions

This would dramatically reduce the requirement for a vast number of library cells and feature definitions to be created
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Display transparent catchment boundary at the cursor when relocating an inlet.

Enable the user when relocating a catch basin to view the catchment boundary as the inlet location is adjusted. Thus, acting as a dynamic and transparent view of the catchment boundary for the inlet at the new location. This will simplify the work...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Enhancement to Create Project Node to Element Tool

There is currently not a way to project a node from the Drainage and Utility Model to an element (horizontal alignment’s profile model). Profile runs can be created and then projected onto the profile model by conduit linkage. With this enhancemen...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Show the Link Size within the Link Summary Tab

The window that pops up after a hydraulic model run for design or analysis includes a "Calculation Detailed Summary". The Link Summary tab does not currently show the designed link size. Showing the link size in the Link Summary tab will allow the...