Drainage and Utilities

Showing 118

Individually Define Maximum Spread

in Drainage and Utilities, remove the Maximum Spread (global for the dgn file) and make it editable for each individual node. Roadways have lots of different gutters etc so I don't want a max spread for the whole file, I want individually.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Already exists

Needs ability to set RIM Depression Depth

Needs ability to add RIM Depression Depth with elevation (ground). Currently we can only set the Elevation (RIm) but not any depression value.
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Place a sanitary pipe that follows a terrain at a specific depth of cover.

It appears that the software currently doesn’t allow sanitary conduit FDs to follow a slope even when the FD is set to depth of cover. it would be nice to tell the program to follow a given depth under the terrain, so I can see the pipe slope vary...
9 months ago in Drainage and Utilities 9 Already exists

ORD D&U - Import / Export WaterCAD models

Ability to import /export to network data from/to OpenFlows WaterCAD in order to collaborate with BIM workflows.
9 months ago in Drainage and Utilities 0 Needs review

Display and Annotate Tap Nodes in Profile Drawing

The feature name (e.g. a number) of the tap node can be labeled in the plan.The tap is visible in the "Engineering Profile".It would be helpful if this could also be displayed and labeled in the profile view/drawing. How it should work: Tap Node i...
about 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

External model checking process - by possibly running a report to identify where 3d conduit string lines have been placed - i.e soffit, centre, invert, crown or base, this will ensure all output data of conduits are consistent for construction.

This is useful to enable a) - checks to be carried out, b) - to identify possible conduits that require amending - to align with all others. This will enable consistent and accurate output data to be produced, that can be used to construct from.
9 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

limit the number of Rows in the Elevation-Area Table.

I get close to 40-50 rows of data when I assign a "pond" to a terrian. I only need data every 0.1ft but it is providing much more.
about 1 year ago in Drainage and Utilities 0 Future consideration

Allow Conduits from different "families" to connect to the same node.

Add support for nodes that accept multiple types of conduit families.
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Ditches be channel features

It would be wonderful if ditches were channel features so that they could be treated as surface features like gutters are to get head on inlet.
10 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Custom Grate Spacing and Sizes

It would be amazing if we could utilize our own grate spacing for calculating the head on inlets. KYTC has several grates that don't quite match with what is in the delivered system, and this may affect the depth of the head on the inlet.
10 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review