Add baseline station and offset references to drainage conduits similar to nodes

I really like how nodes allow you to add a baseline station and offset. This makes it so we can directly copy and paste drainage information from flex tables to summaries, etc. It would be extremely helpful if something similar existed for pipes w...

Allow Sorting of Drainage and Utilities Items in the Project Explorer

Currently, items in the drainage and utilities model in the project explorer appear in the order they were created. However, as element names change, items can be difficult to find especially if there are a lot of elements in the model. It would b...

Need an "Update" tool to update Drainage Catalogs, Prototypes, and Engineering Libraries from another file

We need a better way to update a working DGN with changed or added Drainage content from the DGNLib. It is possible to export and import library XML files, but you'd need to know which libraries have been changed. There's no XML file for prototype...

Add IFC mapping options to elements

The possibility to choose how your objects will be exported to ifc: at the moment everything exports as ifcBuildingElementProxy class, MeshElement type.Example: assign surface templates (pavements) to export as ifcSlab; a retaining wall as ifcWall...

Integrate ESRI ArcGIS geodatabase natively

There is a ton of information stored in GIS. Having the ability to natively and easily view Maps/Layers within a DGN File would be hugely beneficial.

DU: IFC export

It`s not possible to export Drainage and Utilities elements to IFC.There is a way to achive something similar, bur you have to export to iModel, upload it to design review and from there, export to IFC.Major issue for BIM projects and for those wi...
almost 2 years ago in Import/Export / OpenRail Designer / OpenRoads Designer / OpenSite Designer 9 Shipped

Replacement for the GEOPAK Survey Best Fit Tool

The best fit tools we have found in ORD will not create a single linear element and instead creates a complex line or usually with arcs. Specifically for recreating existing Right-of-Way lines, we often have a large number of points, but need only...
over 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 4 Shipped

IFC Export to support export of all elements in the DGN and attached item types

IFC Export to support export of all elements in the DGN and attached item types. Direct export to IFC is required to improve efficiency given that the only way to achieve this at present is to export from iTwin. Improved support for IFC versions a...
about 2 years ago in Import/Export / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Shipped

Update/Modify Profile Run

Named boundary and respective cut-sheet is based on the profile Run Alignment. In further submittal there might be a change (about 25-30%) in the Profile Run of respective system. If we delete the run the named boundary and cut-sheet will lose the...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Shipped

Don't load nested references when nesting is disabled

When a reference is loaded, all its nested attachments are loaded as well. This takes a lot of time, while the nested attachments are not used. Loading nested attachments based on the nesting number would greatly speed up the opening of files