Allow negative surface depth for Overlay Components
It is helpful to have corridor overlay components that follow the surface for the bottom option, and follow a set distance above the surface for the top option. This was achievable in PowerGeopak SS10 by inputting a negative number for the surface...
As an MX user, we had the ability to lock stationing to an xy coordinate in an alignment. Please add this ability in ORD. An example use would be as follows: the user has a complex horizontal alignment, vertical alignment, and wants to append a ta...
Productivity enhancements to Corridor Objects dialog
There are currently some things needed to be added to the Corridor Object dialog to help communicate design intent a bit better to users (especially with Parametric Constraints): The lack of information as to the rules linked to Parametric Constra...
Retain or be able to re-associate references when "One DGN Per Sheet" used to facilitate ProjectWise Integration
Many companies/DOT's use ProjectWise Explorer Client which will apply attributes such as sheet number and total sheets to sheet models via tags. The only way to apply this on multiple sheets is to use the "One DGN Per Sheet" option. If a reference...
Support use of cell definitions for sleeper placements. Long sleeper sets placed at turnout locations, have variable width so these will still be using existing box shaped sleepers but normal sleepers will be using the cell based definitions. This...
When placing a civil labeler, the text displays the field formula and that usually is some big text. The leader placement preview takes this enormous text in consideration and 99% of the times the placement we get is off from the desired, because ...
Add an option to include "Profile" when offsetting Geometry
There should be an option to include the Profile when offsetting geometry if desired. Currently we need to offset the geometry and then copy the profile. It would be much more intuitive if there was an option to just include the profile when initi...
DU conduits external wall controled by Feature Symbology
We have the option to define a template to pipes external walls, but only through the feature definition. For all other elements of the pipe, OR allows for feature symbology. From my experience, symbologys work better and are more constant.
Ability to lock profile when start stationing changes
Right now (2022 R1) if an alignment with a profile is extended in the start, the profile moves together with the start of the alignment. Two wishes: Possibility to lock the profile elements in their present position. Possibility to move the whole ...