Abutment back batter negative

It would be very useful to have the possibility to create a negative back batter (narrow bottom) for an abutment, since currently the back batter can only be positive (wider bottom).
about 1 month ago in OpenBridge Modeler 0 Future consideration

Option to turn off the cut backwall with wingwall

The automated ''Cut Backwall with Wingwall'' of OBM 2023 release is very practical but it would be usefull to have the option to turn it off in some particular situation. e.g. When we want the Wingwall to go all through the front of the StemWall o...
about 1 month ago in OpenBridge Modeler 0 Future consideration

Upgrading from XSLT 1.0 to XSLT 3.0

XSLT 3.0 introduces several new features and improvements that can enhance the development process, increase efficiency, and provide better results. Performance Improvements: XSLT 3.0 includes optimizations that can significantly improve the perfo...

Concrete Diaphragm at Piers for Steel Girder Bridges

Concrete diaphragms can only be placed at the abutments for the bridges with steel girders at the moment. There is no option the define concrete diaphragm at the piers for steel bridges. Users should be able to define concrete diaphragms at the pi...
4 months ago in OpenBridge Modeler 0 Future consideration

Civil Labeler - Add capability to incorporate cells alongside text favorites

We have several annotations that require a combination of cell and civil element data. I've attached 2 examples where we have a need to combine cell with text favorite data. While the text favorite can be added within the cell itself, there are ti...
3 months ago in Annotation / OpenBridge Modeler / OpenRoads Designer / OpenSite Designer 0 Future consideration

Re-word the Upgrade dialog to include that the file will also be 'aligned' to the product.

There are several ways a file can be opened though local access, networking, and ProjectWise. There is very minimal documentation available to explain to users the difference between Upgrading and Aligning a file. Not to mention how, when, and why...

Retain or be able to re-associate references when "One DGN Per Sheet" used to facilitate ProjectWise Integration

Many companies/DOT's use ProjectWise Explorer Client which will apply attributes such as sheet number and total sheets to sheet models via tags. The only way to apply this on multiple sheets is to use the "One DGN Per Sheet" option. If a reference...

Including OverBridges, Noise wall and Large Gantries for Sight distance analysis

For the sight distance analysis, it would be good to include more complex scenarios, like OverBridges, noisewalls, Large Signage Gantries etc. which cannot be included in composite design surfaces.
almost 2 years ago in All Other / OpenBridge Designer / OpenBridge Modeler / OpenRail Designer / OpenRoads Designer / OpenSite Designer / OpenTunnel Designer 1 Future consideration

Allow option to label Terrain Contours using Lines/Linestrings to define paths

We regularly need to deliver contour plans to the client based on Terrains that constantly change as a 3d design develops. It is currently very hard to produce consistent contour outputs because of the manual nature of how the annotation is applie...
almost 2 years ago in OpenBridge Designer / OpenBridge Modeler / OpenRail Designer / OpenRoads Designer / OpenSite Designer / Terrain 3 Future consideration

Adding post tensioning ducts in ProConcrete

ProConcrete allows to add main and secondary rebars to a concrete element (bent, column, or footing) but it does not allow to add post tensioning strands, ducts, trumpets, wedges, or any other element associated to the post tensioning. It would be...
6 months ago in OpenBridge Modeler 0 Future consideration